GasCheck G Technical Specifications
GasCheck G Technical Specifications |
| Detector |
Micro thermal conductivity detector (MTCD) Sensor is poison resistant with over range protection |
| Flow Rate |
2 cc/min |
| Sensitivity (cc/sec) |
He1 x 10-6, CH4 5 x 10-6, R12 5 x 10-5 Ar 1 x 10-4 |
| Operation |
Battery type: 4x alkaline AA size or NiMH (rechargeable) Typically 40 hours life |
| Response |
T90 - 1 second rise and clear down |
| Accuracy |
5% displayed reading one digit |
| Sound |
Flashing LED and 90 dBA (10cm) audible sounder |
| Data logging* |
10 data points with date and time stamp |
| Calibration |
Calibrated to UKAS/NIST standards. |
| Operating temperature |
-20 to 60ºC, -4 to 140ºF |
| Humidity |
0 – 99% RH (non-condensing) |
| Storage temperature |
-20 to 70ºC, -4 to 158ºF |
| Weight/Dimensions |
Case: 420 x 320 x 97mm, 16.5 x 12.5 x 3.8” Instrument: 0.45 kg, 1 lb, Packed 1.6 kg, 3.5 lb Instrument with probe: 390 x 60 x 49mm, 15.5 x 2.3 x 1.9” |
|
|
EMC tested EN50081-1 & EN50082-1 July 98