Advanced Gas Sensing Technologies
Product Details
FirstCheck+ Handheld Multi Gas Detector

Firstcheck+ is the first ppb multi gas detector to combine volatile organic compound (VOC) detection with explosive gas (LEL) sensors. Its multi gas sensors detect oxygen, hydrogen sulphide, carbon monoxide and explosive gases, using a highly sensitive PID detector.
The FirstCheck+ handheld multi gas detector provides unrivalled resistance to humidity, due to its unique Fence Electrode Technology. The instrument's PID capabilities have received independent verification as the most sensitive, accurate PID available.
FirstCheck+ accurately detects VOCs from 1 ppb to 10,000 ppm, a range unmatched by other multi gas detector. The FirstCheck+ multi gas detector enables the detection of many gases that are toxic at low ppb levels.
The Firstcheck+ gives rapid response at the scene of an accident or emergency enabling fast action to be taken. Firstcheck+ is the multi gas detector of choice for applications including emergency response, confined space entry, weapons of mass destruction and hazardous materials
DETECTOR
For details of each sensor, its range and response time please see the FirstCheck+ Sensor Specification table.
INTRINSICALLY SAFE APPROVALS
II2 G Baseefa 03ATEX0742
Ex iad IIC T4 (-20 oC ≤ Ta ≤ 60 oC)
IECEx BAS 04.0033 (world standard)
ACCURACY*
± 5% displayed reading at calibration point
LINEARITY*
± 5%
DATA LOGGING
Automatically recording all 5 sensors every second including date and time stamp
8 Mb (expandable) data memory
Incorporates a secure storage algorithm to reduce stored data corruption
CALIBRATION
Via calibration kit accessory
OPERATION
Dry Cell: Alkaline 4 x AA:11 hours
ALARM
Flashing LED and 90 dBA (10cm) audible sounder
User set and TWA & STEL
Pre-programmed 450+ gases and gas mixtures
FLOW RATE
220 ml/min or 220 cc/min with flow fail alarm
TEMPERATURE
Operating: -20 to 60 oC, -4 to 140 oF
Humidity: 0-99% RH (non condensing)
WEIGHT & DIMENSIONS
Instrument without probe
340 x 60 x 49 mm (13.5 x 2.3 x 1.9”)
Standard case 420 x 320 x 97 mm (16.5 x 12.5 x 3.8”)
Instrument 0.615 kg (1.36 lb)
Packed 3.045 kg (6.7 lb)
NB: PID specifications relate to an isobutylene 100 ppm in air calibration at 20oC and 90% RH. LEL specifications relate to a methane (CH4) calibration, other gases available on request. Other gas sensors as specified at appropriate international alarm standards.*Assuming constant environmental conditions.
Note: Fence Electrode Technology is produced by Ion Science Ltd, and protected by U.S. Patent No. 7,046,012. EP 1474681,other patents pending.
The FirstCheck+ multi gas detector detects gases across a number of applications, including:
The following FirstCheck+ Handheld Multi Gas Detector documents can be downloaded below. To obtain hard copies of any of the items, please email info@ionscience.com
The following accessories are available for the FirstCheck+ Handheld Multi Gas Detector. For further information or pricing please contact Ion Science or your local Distributor.
| Part Number | Description |
| 1/EK-02 | Sensor LEL |
| 1/EK-03 | Sensor Carbon Monoxide |
| 1/EK-04 | Sensor Hydrogen Sulphide |
| 1/EK-05 | Sensor Oxygen |
| 1/VC-19 | Belkin USB Infrared Smart beam |
| 1/VS-20 | 9V Multi Head Uni Power Adapt |
| 30618 | 8.4Ev Lamp (Xenon) |
| 30620 | 10.6Ev Lamp (Krypton) |
| 30621 | 11.7Ev Lamp (Argon) |
| 30626 | 10.6ev Lamp (Krypton) High Energy |
| 31052 | Jacket For PhoCheck Instrument |
| 5/BS-01 | Calibration Gas Isobutylene 100ppm (103 litres) |
| 5/BS-02 | Calibration Gas H2S/CO/CH4/Air (58 litres) |
| 5/RD-01 | Demand Flow Regulator |
| 845253 | Sample Probe Collapsible |
| 845254 | Sample Probe Aluminium |
| A-30555 | Light-Weight Probe 5M |
| A-30556 | Light-Weight Probe 10M |
| A-30625 | Light-Weight Probe 15M |
| A-31057 | Carbon Filter Assembly (Sm Blue) |
| A-31063 | PID Lamp Cleaning Kit |
| A-31064 | Filters, 25mm Dia, Box Of 5 |
| A-31066 | Extra Std Probes Box 5 |
| A-31088 | Lamp Removal Tool |
| A-31104 | Filters, 25mm Dia, Pk 100 |
| A-31117 | AAA Battery Pack (battery charger & adaptor) |
| A-31142 | PID Accessory Kit |
| A-31146 | Secondary Probe Filter (pack of 5) |
| A-31153 | Exhaust Barb (Packed) |
| A-31158 | High Temperature Probe |
| A-70023 | Gas Diluter |
| A-820113 | Battery Clip Assembly |
| A-820213 | FirstCheck Calibration Kit |
| A-820229 | Calibration Adaptor |
| A-820233 | Car Charger (12V) |
| A-830206 | Decontamination Bag ( 10 Off ) |
| A-845213 | PID Calibration Kit 100ppm Isobutylene (103 litres) |
| A-845214 | PhoCheck Demand Calibration Kit |
| A-845215 | PhoDock Docking Station |
| A-845216 | PhoDock Calibration Adaptor |
| A-845234 | PhoCheck+ Inst Jacket with magnets |

The FirstCheck+ multi gas detector is a fully upgradeable instrument available in four distinct variants. Choose the instrument to best suit your requirements.
FirstCheck+ 1000Ex
Intrinsically Safe with a detection range of 0.1 – 4,000 ppm, the FirstCheck+ 1000 has user set single point alarms and gas table of over 450 gases (including their unique response factors.)
FirstCheck+ 2000Ex
With added data logging capability, the FirstCheck+ 2000 allows storage of over 37 hours of data logged readings taken every second (over 130,000 individual readings!) The FirstCheck+ 2000 multi gas detector has a date and time stamp for download to a PC via an IRDA link for detailed analysis.
FirstCheck+ 3000Ex
In addition to the features above, FirstCheck+ 3000 has an extended detection range of 0.1 to 10,000 ppm and additional operating mode for health and safety monitoring with pre-programmed STEL and TWA values.
FirstCheck+ 5000Ex
The most sophisticated multi gas detector, the FirstCheck+ 5000 provides full features and a dynamic detection range of 1 ppb to 10,000 ppm. Dangerous toxic gases can be detected at low ppb levels where hazardous to health, as well as flammable gases at LEL thresholds. Ideal for the First Responder, the sensitivity of the FirstCheck+ 5000 multi gas detector is a potential life saving instrument in the most hazardous environments. Its inert flow path ensures optimal response to heavy and reactive chemicals - not detected by other units - such as MDI, Mustard and Tabun.
FirstCheck+ 5000Ex Rechargeable includes: