ionscience.com / Products / GasClam Portable Gas Monitor

Product Details

GasClam Portable Gas Monitor

GasClam® - Continuous Ground Gas Monitor

GasClam – portable ground gas monitor

Monitor CH4, O2, O2, CO2, CO, H2S and VOCs continuously, for up to 3 months!

GasClam is the first ground gas monitor to give continuous, unmanned data collection. Ideal for landfill gas monitoring applications, the GasClam ground gas monitor logs long-term, real trend information. A revolution in gas management and risk prediction, informed decisions can now be made on accurate, reliable data. 

The GasClam gas monitor measures methane, carbon dioxide and oxygen concentrations as well as atmospheric pressure and temperature. Optional CO, H2S and VOC, plus water depth are available along with a telemetry module for remote, real time data communication.

The gas monitor’s sampling frequency can be set and is variable from two minutes, to once daily. Data is downloaded to a PC or viewed remotely using the optional GPRS telemetry system.

Manufactured from stainless steel, the GasClam ground gas monitor is Intrinsically Safe, environmentally sealed and ingress protection rated IP-68. Battery operated; GasClam can be powered for up to 1 month based on hourly sampling.

GasClam is a registered trademark of Ion Science Ltd.

Features

GasClam Gas Monitor Features:

  • Three months continuous data collection
  • Secure unmanned operation
  • Methane (CH4), Oxygen (O2), and Carbon Dioxide (CO2)
  • Temperature, Borehole and Atmospheric Pressure
  • Optional CO, H2S or VOC plus water depth
  • Telemetry module for remote real time data communication
  • ATEX (IECEX) approved
  • Battery operated
  • Ingress protection rated IP68
  • RS 232 communication
  • Intrinsically safe

Benefits:

  • Reduction of unnecessary site visits
  • Complete data for a full site assessment
  • Demonstrates full due diligence
  • Meets all legislative needs
  • Data including barometric pressure logged simultaneously
  • Data can be downloaded on site for quick analysis
  • Events captured with a time and date stamp
  • Removal of any uncertainty in gas monitoring regime
  • Assists with design of gas protection measures
  • Validates operation for Biogas production
  • Also can monitor greenhouse - gas emissions
  • A post site development monitor for extra safety
  • Optional Carbon Monoxide (CO) or volatile organic compound (VOC) sensor for specific applications
  • Optional water depth sensor where ground water influences results
  • Control vent boreholes to measure concentration build up times
  • Optional telemetry system for real-time monitoring on critical sites

Specification

GasClam Technical Specification

  • Memory – 65000 time/date stamped readings
  • Power – Internal x 2 Alkaline D-cells
  • Battery Life – Approximately 1 month (hourly sampling with rechargeable battery)
  • Case – High Quality Stainless steel
  • Weight – 6 kg or 13.2lb
  • Dimensions - Overall Length 85cm or 33½ inches
    Borehole Tube Length 78cm or 30¾ inches
    Head Diameter 10.9cm or 4¼ inches
    Borehole Tube Diameter 4.3cm or 1¾ inches
  • Protection - IP-68 (continuous submersion)
  • Operation temperature -5 0C to + 50 0C or 23 0F to 122 0F
  • Approvals – CE , EMC, ATEX 0105 X, Ex II 2G, Ex d ib [ib] IIB T4
  • Approvals pending - IECEX UL and CSA
  • World-Wide Patent Pending
Gases Method/Type Range Resolution Accuracy Linearity
CH4** Infra-red 0-100%
or 0-5%
1% of FSD above 50%,
0.5% below 50%
+/- 2% FSD +/- 2% FSD or 10% reading
CO2** Infra-red 0-100%
or 0-5%
1% of FSD above 50%,
0.5% below 50%
+/- 2% FSD +/- 2% FSD or 10% reading
Oxygen Electrochemical 0-25% vol 0.1% vol +/- 5% of reading +/- 1 digit >1% O2 deviations@10% O2
CO* Electrochemical 0-1000 ppm 1 ppm +/- 6 ppm at 0,
+/- 5% at 250 ppm
Linear at 0 and 400 ppm,
error at full scale <40 ppm
H2S* Electrochemical 0-100 ppm 1 ppm +/- 1 ppm at 0,
+/- 5% at 50 ppm
Linear at 0 and 20 ppm,
error at full scale 0 to -9 ppm
VOC* PID 0-4000 ppm 1 ppm +/- 5% of reading +/- 1 digit +/- 5% to 100 ppm
Environment Method/Type Range Resolution
Temperature Internal Chip - 5°C to + 50°C or 41°F to 122°F 1°C or 1°F
Barometric Piezoelectric 800 to 1200mb 1mb
Borehole Piezoelectric 800 to 1200mb 1mb
Water Depth* Piezoelectric 0 to 25m 0.01m

* Optional
** Choice of any 2 IR sensors, specify on order

Specifications obtained under laboratory conditions of gas flow, temperature and humidity. Field performance is dependant on the correct installation procedures being followed, environmental conditions, frequent sensor cleaning and regular calibration. CH4 sensor is calibrated for CH4 but detects a range of hydrocarbons. Details are subject to change without notice.

Applications

Key applications for the GasClam ground gas monitor include:

  • Hydro-fracking
  • Vapour Intrusion
  • Landfill gas monitoring for long term profiling
  • Brownfield for development issues
  • Below ground carbon capture
  • CO2 sequestration
  • Monitoring for coal mine fires
  • Leakage in crude/petroleum
  • Solvent storage and filling stations
  • Refineries for local compliance
  • Storage monitoring regimes

On Landfill Sites

  • Perimeter monitoring using existing boreholes
  • Accurate real-time measurement of Green House gases.
  • Discharge of licence when used as a post-closure monitor
  • Spontaneous combustion detection
  • Long term monitoring

On Brownfield sites and Disused Coal Mines

  • Site investigation
  • Validation of any remediation untaken or needed
  • After site development validation and monitoring
  • General due diligence

Below Ground Carbon Capture and Storage:

  • Validation of storage sites: peat bogs, etc
  • Long term site surveys for suitability
  • Validation of compliance

For Petroleum/ Solvent Storage and Filling Stations:

  • Leak site investigation
  • Perimeter monitoring
  • Early validation of effective bunding or need to repair
  • Long term spillage monitoring
  • Compliance to the Regulations

On Refineries:

  • An integral part of long term monitoring procedures
  • An independent check on other monitoring techniques
  • Incident use after spillage
  • Demonstration of due diligence
  • C02 sequestration monitoring

Downloads

The following GasClam Portable Gas Monitor documents can be downloaded below. To obtain hard copies of any of the items, please email info@ionscience.com

Papers

A number of GasClam papers are available below for download, or to read in more details, visit the GasClam Papers page.

Accessories

The following accessories are available for the GasClam Portable Gas Monitor. For further information or pricing please contact Ion Science or your local Distributor.

Part Number Description
1/VC-18 USB 2.0 To Rs-232 Adapter
25062 Charger NiMH ECH
25063 Display Unit EDA
25065 Re-chargeable Battery Pack
25071 GSM / GPRS Modem for GasClam
25072 Dual Antenna with Holder for GasClam
25039 Water Level Sensor (6m) – also available in 1.5m, 2m, 2.5m and 3m

What’s Included?

The GasClam gas monitor is available in four variants:

Part Number Description
BMSSABXG-X GasClam (standard)
BMVSABXG-X GasClam (standard) with VOC
BMSSABXG-D GasClam (standard) with H2S / CO
BMVSABXG-D GasClam (standard) with H2S / CO and VOC

What’s in the Kit

GasClam (standard) includes:

  • GasClam Gas Monitor (fitted with Oxygen Sensor, Carbon Dioxide Sensor, HydroCarbon Sensor, Rubber Collar, 2 x 1.5v Duracell Batteries)
  • GasClam Carry Bag
  • GasClam Software CD
  • GasClam Manual
  • Snorkel (Comes with filter and 30cm pipe)
  • Communications Cable
  • Start Cable
  • Tool Kit
  • Blank for vent port

For further information and pricing please contact Ion Science or your local Distributor.

  • UK Sales +44­ (0)­ 1763­ 208503
  • US Sales +1­ 877­ 864­ 7710
  • DE Sales +49­ 2104­ 14480

GasClam Portable Gas Monitor Enquiries

Please complete the form to request a call back from our product specialists. * Required fields.

Please enter the anti spam code below:

verification code

Product Testimonials

GasClam Ground Gas Monitor

"Newcastle-under-Lyme Borough Council has been utilising a GasClam in a number of Part IIA site investigations where ground gas has been identified as a key risk driver. High quality, reliable, continuous data obtained alongside traditional ‘spot sampling’ provided greater insight into the gas regime of the site and served to reduce uncertainty whilst increasing confidence in the overall conclusions drawn from the data. This in turn reduced the monitoring period required and time and financial savings to be made" Read more.

Bo Simkin, Contaminated Land Officer, Newcastle under Lyme Borough Council


To read more Testimonials on our products, please visit our 'What Our Customers Say' page