TIGER LT

Handheld VOC gas detector

TIGERLT is an entry-level handheld VOC detector that provides fast, accurate, reliable results, however challenging your environment.

This variant of the hugely popular Tiger VOC detector is low on cost but high on performance. Its revolutionary, patented photoionisation detection (PID) sensor technology with humidity resistance and anti-contamination design provide market leading accuracy and run-time.

Combined with 24-hour battery life, its features maximise field time by minimising inaccurate readings in high humidity and drift in harsh environments.

TIGERLT accurately detects gases from 0 to 5,000 ppm with a 0.1 ppm minimum sensitivity, has the fastest response time on the market of just two seconds, and is as quick to clear down. Its push-to-log data logging stores up to 80,000 data points in up to 128 user selectable zones.

This instrument has been designed with the user in mind for ease of use and servicing. Batteries can be replaced in potentially explosive environments due to the innovative Intrinsically Safe design. Low-cost filters and lamps can be easily changed in minutes, minimising instrument downtime. Fast battery charging allows the instrument to be fully charged in just six hours.

TIGERLT offers simple, one-handed operation even when wearing the thickest of gloves. Its rugged design and protective, removable rubber boot withstand harsh environments.

The large, clear backlit display allows for easy viewing in any light condition. An integrated torch is designed for directing the instrument’s probe into dimly lit areas. The illuminated keypad activates when the light is low.

TIGERLT is a ground-breaking, low-cost entry level PID with all the essential functions you need for VOC detection. The instrument has the lowest running costs on the market with inexpensive disposable parts, lamps and filters.

Ion Science VOC detectors all incorporate leading PID sensor technology which has received independent verification as the best performing on the market for its speed of response, accuracy and linearity.

See our range of leading VOC detectors:

Entry level Handheld VOC detector

Key Features

Ease of use

  • User selectable response factors for direct concentration readout
  • Intuitive, easy to use software
  • Large clear keypad for easy operation when wearing gloves
  • Ergonomic design allows simple one handed operation
  • Large, clear visual display
  • Torch and back-lit keypad for low light conditions
  • Push-to-log data logging, 128 zones, 80,000 points
  • Designed for easy service

Best available PID technology

  • PID independently verified as best performing on the market
  • Accurate results across all environments from 0 – 5000 ppm
  • Minimum sensitivity 0.1 ppm (100 ppb)
  • Patented humidity resistance to 99% RH – no compensation needed
  • Anti-contamination design minimises drift and extends run time
  • Fastest 2 second response time and rapid clear down

Minimise downtime

  • Anti-contamination design reduces calibration frequency
  • Li-ion battery for up to 24 hours continuous operation
  • 6.5 hours battery charge time maximises uptime
  • Batteries field replaceable, even in explosive environments
  • Filters and lamps replaceable in minutes
  • Simple icon driven menu requires minimal user training

Safety

  • 95 dBA, bright LED and vibration alarms alert you to gases present
  • Intrinsically safe; meets ATEX, IECEx, UL and CSA standards

Low cost

  • Entry level VOC detector with all the essential functions
  • Inexpensive consumables and parts for low cost operation
Entry level Handheld VOC detector

What’s included

Further details can be found below. For more information and prices contact Ion Science or your local Distributor.

TIGERLT Kit (part no. PTLSLBMR-0000):

  • TIGERLT instrument
  • Rechargeable battery (Li-ion)
  • Battery charger and mains adaptor
  • Rubber boot
  • Lightweight carry case
  • Explorer case*
  • PTFE filter disc (dust filter)
  • Removal tool for MiniPID Stack
  • Sample cleaning compound assembly
  • Cleaning buds
  • Lanyard (wrist strap)*
  • USB cable
  • Carbon filter*
  • Calibration adaptor*
  • Sensor seal (coated)*

* Items only available with premium kit orders

Tiger LT Product downloads


Product downloads - Ion ScienceFor all downloadable resources please click here

Brochure, Manual, Quick Start Guide, Software, Video and Articles.

Technical Specification

Technical Specification

Value/Information

Minimum Resolution*0.1 ppm
Maximum Reading**5,000 ppm
Response TimeT90 < 2 seconds
Accuracy*± 5% display reading ± one digit
Linearity*± 5% display reading ± one digit
Intrinsically Safe ApprovalsII 1G Ex ia IIC T4 Ga
Tamb = – 15 0C ≤Ta ≤+45 0C (with lithium ion battery pack) Tamb = – 15 0C ≤Ta ≤+40 0C (with alkaline battery pack) ITS09ATEX26890X IECEx ITS 10.0036X
3193491 conforms to UL Std. 913, 61010-1 &
Certified to CAN/CSA Std. C22.2 No. 61010-1
Battery LifeLi-ion: life up to 24 hours continual use
Lamps10.6 eV Krypton PID lamp
Data LoggingPush-to-log, 128 zones, 80,000 data points
CalibrationStandard calibration 100 ppm isobutylene
Custom calibration capability
AlarmFlashing LED and 95 dBA at 300mm (12”) audible sounder
Selectable vibrating alarm
Flow Rate ≥ 220 ml/min in Ambient conditions
Temperature Operating: -20 to 60oC, -4 to 140oF (non-Intrinsically Safe)
Humidity: 0-99% RH (non condensing)
ProtectionDesigned to IP65 (heavy rain)
1180
EMC tested to EN61326-1:2006, EN50270:2006 & CFR 47:2008 Class A
Weight & Dimensions367 mm height (14.45”) 89 mm Width (3.54”) 60mm Depth (2.36”)
Instrument weight 0.72 kg (1.56lb)

All specifications are against isobutylene calibration at 20oC, 90% RH and up to 3000 ppm unless otherwise stated. *Gas dependent.

Downloads

Video Support

Video Support – TigerLT VOC detector

Product Testimonials

TigerLT VOC detector

Product Enquiries

If you would like a member of our team to discuss your needs and questions relating to this product, please click the enquire button below now.

Technical Support

If you already have this instrument and have a technical enquiry, please call us on the number below.

Accessories

The following accessories are available for the TigerLT VOC detector.
For further information or pricing please contact Ion Science or your local Distributor.

Tiger LT Enquiry Form

Product Enquiry Form

Please complete the form below and a member of our team will contact you.

Fields marked with an * are required