tiger_select_benzene_gas_detector

Tiger Select

Portable benzene gas detector

The Tiger Select is a portable benzene gas detector with two operation modes for rapid detection of benzene and Total Aromatic Compounds (TACs) providing accurate, reliable data.

Tiger Select portable benzene gas detector is capable of providing 15-minute short-term exposure limits (STELs) and 8-hour time-weighted averages (TWAs) for total aromatic compounds (TACs).

etl_certificationIECEx certificationATEX certficationkgs_certification

Enquire NowDownload Brochure
tiger_select_portable_benzene_detector

Features

The Tiger Select portable benzene gas detector, displays real-time data, ensuring the final reading represents the full value of actual benzene present. Benzene concentrations are displayed down to parts-per-billion (ppb) levels, giving you accurate, reliable data you can count on.

Tiger Select can also be used in ‘standard Tiger operational mode‘ without the use of a benzene pre-filter tube to deliver active indications of volatile organic compounds (VOCs), including benzene, at concentrations as low as 1 ppb benzene equivalent.

There are 3 gas detection instruments in the Tiger range, the other two include Tiger and Tiger LT.

Ultimate Performance

  • Unrivalled sensitivity detects down to ppb levels
  • Selectively detects benzene with ION Science pre-filter tube
  • In-built humidity resistance with no need to compensate
  • Anti-contamination design for extended field operation

Ultimate Safety

  • Large battery capacity gives several days of use
  • Torch and back-lit keypad for low light conditions
  • Batteries field replaceable, even in explosive environments
  • 95 dBA, bright LED and vibration alarms alert you to gases present

Ultimate Flexibility

  • Simple icon driven menu requires minimal user training
  • Filters and lamps replaceable in minutes
  • Li-ion battery for up to 24 hours continuous operation
  • Five year warranty when instrument registered online

Technical Specification

etl_certificationIECEx certificationATEX certficationkgs_certification

Specification
Value
Minimum Sensitivity PPM Model Standard running mode 0.1 ppm
TAC 0.01 ppm
Tube mode 0.01 ppm (res. 0.001 ppm)
Maximum Sensitivity PPB Model Standard running mode 0.001 ppm
TAC 0.001 ppm
Tube mode 0.01 ppm (res. 0.001 ppm)
Maximum Reading** Standard mode up to 20,000 ppm or 20,000 mg/m3
Tube mode 200 ppm or 639 mg/m3 benzene
Response Time 130 seconds at 20 °C (variable) progressive indication of benzene breakthrough is displayed in real time
Accuracy*** ± 10 % displayed reading ± one digit benzene (tube mode)
Intrinsically Safe Approvals

II 1G Ex ia IIC T4 Ga

Tamb = – 15 °C ≤Ta ≤+45 °C (with lithium ion battery pack)

Tamb = – 15 °C ≤Ta ≤+45 °C (with alkaline battery pack)

ITS09ATEX26890X

IECEx ITS 10.0036X

3193491 conforms to UL Std. 913, 61010-1 & Certified to CAN/CSA std. C22.2 No. 61010-1

Class 1 Division 1. Approval for Groups A, B, C & D, T4

Battery Life

Li-ion: life up to 24 hours, charge time 6.5 hours

Alkaline: 3 x AA, typically 8.5 hours life

Lamps 10.0 eV Krypton PID lamp
Data Logging* 120,000 data log points including date and time stamp
Communication Direct USB 1.1
Calibration 2 and 3 points calibration (via calibration kit accessory)
Alarm Flashing LEDs Amber (low alarm) Red (high alarm)
Sounder 95 dBA at 300 mm (12″)
Vibration on alarm
Pre-programmed TWA and STEL
Flow Rate ≥ 220 ml/min (with blocked flow alarm)
Temperature Operation: – 20 to 60 °C, – 4 to 140 °F (non intrinsically safe)
Humidity: 0 – 99 % RH (non condensing)
Protection Designed to IP65 (heavy rain)
EMC tested E613261:2006, EN50270:2006 & CFR 47:2009 Class A
Weight and Dimensions Instrument (probe fitted, no tube attached) Height: 465 x Width: 89 x Depth: 61 mm (18.3 x 3.5 x 2.4″)
Instrument weight: 0.75 kg
Standard case: packed weight: 5 kg (176 oz)

Specifications are based on Benzene calibrations at 20 °C and 1000mBar
*Model and gas dependent.
**Maximum reading is achieved with certain analytes such as ethanol.
***All specifications quoted are at calibration point and under the same ambient conditions.

Download Brochure

Video Library

Benzene related products from ION Science

With work exposure limits so low it has never been more important to have equipment that can detect benzene down to ppb levels.

Tiger Select – Portable Benzene Gas Detector

The Tiger Select is a portable benzene gas detector with two operation modes for rapid detection of benzene and Total Aromatic Compounds (TACs) providing accurate, reliable data.

Downloads

For further supporting documentation for Tiger Select portable benzene gas detector, please see below.

Tiger Select Portable Benzene Gas Detector Accessories and Replacement Parts

There are a number of accessories and replacement parts available for the Tiger Select portable benzene gas detector, which can be found below. Please contact us if you would like more information or to place an order.

FAQs

If you have any further questions, please enquire now.

Are ION Science part of the WEEE Compliance Scheme?

How do I upgrade my Tiger PC software?

What response factor do I need?

Tiger Select Portable Benzene Gas Detector Enquiry Form

Please complete the form below and a member of our team will contact you shortly.

Global Distributors

All ION Science distributors are trained to the highest standards to provide you with access to our product portfolio locally, along with the best possible service and support. Find your local representative.